L-CNG Cryogenic plug pump skid
L-CNG Cryogenic plug pump skid
Air tightness test: 25 MPa
Design pressure: 1.6MPa before pump, 27.5MPa after pump
Working pressure: 1.2MPa before pump, 25MPa after pump
Temperature range: -196°C-55°C
Pipe material: 304 stainless steel
Single pump flow range: ≤4000L/h
Cold insulation method: polyurethane foam / vacuum tube
Number of pump configurations: 1 pump, 2 pumps, 3 pumps and multiple pumps
Maximum test pressure: 30MPa
Applicable medium: LNG or liquid nitrogen
Automatic control of each pipeline solenoid valve
Increase the liquid low pressure LNG pressure from 0.5MPa to 20-25MPa
The entire pump can be fully controlled and fully automated according to the control method
The operation of the two pumps does not affect each other and can be operated either separately or simultaneously.